Isotropic Broadband Magnetic Field Probe PI-H1 0.5MHz-50MHz

Isotropic Broadband Magnetic Field Probe PI-H1:

500 KHz -50 MHz, 0.05 – 20 A/m

State of the art probe PI-H1 is used for assessment of the limits for maximum permissible exposure of occupational and general population to RF magnetic fields. Probe covers the frequencies of major industrial, broadcast and telecommunication sources, has flat response in the pass band 2-50 MHz and usable response to 500 KHz (with correction factors), eliminating the typical need for two probes. PI-H1 probe is very compact, rugged and offers good magnetic field overload capability and pick up suppression of the out-of-band electric and magnetic fields.

 

Magnetic Field Probe PI-H1

Main Parameters

Operates with RFP-05 and RFP-05M meters.

Meter RFP-05

• Sensor: 3-Axial diode based isotropic sensor with orthogonal broadband loops.

• High sensitivity: 0.05 A/m.

• Linearity: +/- 0.5 dB.

• Dynamic range: >50 dB (single range).

• Withstands continuous magnetic field 30 A/m.

• Frequency response (referred to 27.1 MHz): 2 MHz-50 MHz (+0/- 1 dB),

• Frequency response (with correction factors): 500 KHz-50 MHz (+/- 1 dB).

• Rotational isotropicity: +/- 0.6 dB.

• Calibration accuracy (at specified freq.) <0.5 dB.

• E field suppression: 15 dB (at 13.56 MHz).

• Temperature: 5-40°C,

• Humidity: RH 10-90%, non-condensing.

• Temperature error: <0.05 dB/°C (field > 0.1 A/m).

• UK NPL or NIST traceable calibration.

• Small size: LxD: 9.0×2.25 inch, 230×58 mm.

• Weight: 0.2 lb, 100 g.

• Operates with RFP-05 meter.

• Designed and made in the USA.

Magnetic Field Probe PI-H1

Calibration Details:

 – Keep unit calibrated. We recommend calibration once a year in our UK NPL traceable EMC Test Lab.

All calibration tests are perormed in EMC Test Design, LLC test lab and are based on transferable field measuring probes and antennas traceable to United Kingdom National Physical Laboratory (UK NPL).

1)  Meter/Probe Linearity 0.05-20 A/m @6.78 MHz,

2) Probe Frequency Responce at 17 specified frequencies in the frequency range 500 KHz-100 MHz.

3) Probe Rotational isotropicity at 6.78 MHz (@0.5 A/m).

 – To convert the electric field strength E (V/m) into power density S (uW/cm2) use formula: S=E2/3.77. To calculate the value of the magnetic field H (far field region) use the relationship: E/H=377 Ohm.

 

 

 

 

RF Immunity Compliance/Precompliance

RF Immunity testing of electronic products to comply with consumer, military and industrial standards (CE Mark, MIL STD, RTCO, IEC, etc.)

 

Environment:

Typically – laboratory setting with or without a dedicated screen room.

Anechoic chamber in more advanced certified labs.

 

Requirements:

Isotropic probes.

Traceable calibration (NIST, UK NPL).

PC linked.

Fiber Optic Link Kit.

 

Products:

Probes PI-01LF (50 KHz-3 GHz), PI-01 (200 KHz-3 GHz), PI-01E (100 KHz-6 GHz),

PI-03 (3 MHz-18 GHz), PI-05 (1 MHz-40 GHz), Magnetic probe PI-H1 (500 KHz-50 MHz).

Meters: RFP-05/RFP-05M (for multiple probes), RFP-04 (for single dedicated probe).

 

Accessories:

Insulated Modem IM-01 (for RFP-05M).

Optical Digital Link Kit ODLK-01 (for RFP-05).

PC Link Kit PCLK-01 (for RFP-04).

Fiber Optic Link Kit FOLK-02 (for RFP-05M).

Fiber Optic Link Kit FOLK-01 (for RFP-05, RFP-04).

 

RF Safety (except wearable personal safety)

Field monitoring for industrial environment safety compliance

 

Environment:

Industrial floor or labs.

 

Requirements:

Isotropic probes.

Traceable calibration (NIST, UK NPL).

 

Products:

Probes PI-01LF (50 KHz-3 GHz), PI-01 (200 KHz-3 GHz), PI-01E (100 KHz-6 GHz),

PI-03 (3 MHz-18 GHz), PI-05 (1 MHz-40 GHz), Magnetic field probe PI-H1 (500 KHz-50 MHz).

Meters: RFP-05/RFP-05M (for multiple probes), RFP-04 (for single dedicated probe).

 

Accessories:

Insulated Modem IM-01 (for RFP-05M).

Optical Digital Link Kit ODLK-01 (for RFP-05).

PC Link Kit PCLK-01 (for RFP-04).

 

Enviromental and RF “Smog” Monitoring

Monitoring of the environmental RF spectrum, selective or broadband

 

Environment:

In the field, industrial or living spaces, portable or permanently installed, networked.

 

Requirements:

Isotropic probes, isotropic antenna.

Traceable calibration (NIST, UK NPL).

Ability to operate while AC/DC powered and PC network connected.

 

Products:

Probes PI-01LF (50 KHz-3 GHz), PI-01 (200 KHz-3 GHz), PI-01E (100 KHz-6 GHz),

PI-03 (3 MHz-18 GHz), PI-05 (1 MHz-40 GHz), Magnetic field probe PI-H1 (500 KHz-50 MHz).

Meters: RFP-05/RFP-05M (for multiple probes), RFP-04 (for single dedicated probe).

Isotropic Antenna OFA-S/SE (30 MHz-3 GHz).

Selective Field Analyzer SFA-S/SE.

 

Accessories:

Insulated Modem IM-01 (for RFP-05M).

Optical Digital Link Kit ODLK-01 (for RFP-05).

PC Link Kit PCLK-01 (for RFP-04).

Portable Spectrum Analyzer (for OFA-S/SE).

Laptop PC (for SFA-S/SE), unless networked.

 

Order User Manuals or Other Documents

Smart Fieldmeter® and Smart Fieldmeter® Digital Probe Comparison:

Probes Chart 2014

Probes Chart 2014