Isotropic Broadband Electric Field Probe PI-01E : 100 KHz- 6 GHz, 0.3 – 600 V/m
State of the art probe PI-01E, meets the requirements of new EMC and RF safety standards. It allows measurements of RF fields produced by most of the broadcast, telecommunication and industrial sources. This probe eliminates the need for two probes to cover the required frequency range 100 KHz- 6 GHz, thus making measurements simpler and faster.
- Flyer
- Specification
- Calibration Details
- Compatible Products & Accessories
- Solutions
- Additional Documents
Probe PI-01E
for Smart Fieldmeter® and Smart Fieldmeter® Digital meters
Main Parameters
Operates with all meters.
• Diode based: 3-Axial isotropic sensor.
• High sensitivity: 0.3 V/m.
• Linearity: +/- 0.5 dB (1-400 V/m), +/- 1 dB (400-600 V/m).
• Dynamic range: >66 dB (single range).
• Frequency response (without correction factors): 100 KHz-10 MHz (+2.5, -3 dB), 10 MHz-2 GHz (+/- 1 dB), 2-6 GHz (+1, – 4 dB).
• Frequency response (with correction factors): 100 KHz-1 GHz (+/1 dB), 1- 6 GHz (+/- 1.5 dB).
• Rotational isotropicity: <1 dB (typical 0.5 dB).
• Calibration accuracy (at specified freq.) <1 dB.
• Temperature: 5-40°C,
• Humidity: RH 10-90%, non-condensing.
• Temperature error: <0.05 dB/°C (field > 2 V/m).
• UK NPL or NIST traceable calibration.
• Small size: LxD: 9.0×2.25 inch, 230×58 mm.
• Weight: 0.2 lb, 100 g.
• Operates with both RFP-04 and RFP-05 meters.
• Designed and made in the USA.
Calibration Details:
– Keep unit calibrated. We recommend calibration once a year in our UK NPL traceable EMC Test Lab.
All calibration tests are perormed in EMC Test Design, LLC test lab and are based on transferable field measuring probes and antennas traceable to United Kingdom National Physical Laboratory (UK NPL).
Probe PI-01E
1) Meter/Probe Linearity 0.2-600 V/m @100 MHz/72.5 MHz,
2) Probe Frequency Correction Factors at 12 specified frequencies in the frequency range 100 KHz-6 GHz.
3) Probe Rotational isotropicity at 100 MHz & 1900 MHz (@10 V/m).
– To convert the electric field strength E (V/m) into power density S (uW/cm2) use formula: S=E2/3.77. To calculate the value of the magnetic field H (far field region) use the relationship: E/H=377 Ohm.
Compatible Products & Accessories
RF Immunity Compliance/Precompliance
RF Immunity testing of electronic products to comply with consumer, military and industrial standards (CE Mark, MIL STD, RTCO, IEC, etc.)
Environment:
Typically – laboratory setting with or without a dedicated screen room.
Anechoic chamber in more advanced certified labs.
Requirements:
Isotropic probes.
Traceable calibration (NIST, UK NPL).
PC linked.
Fiber Optic Link Kit.
Products:
Probes PI-01LF (50 KHz-3 GHz), PI-01 (200 KHz-3 GHz), PI-01E (100 KHz-6 GHz),
PI-03 (3 MHz-18 GHz), PI-05 (1 MHz-40 GHz), Magnetic probe PI-H1 (500 KHz-50 MHz).
Meters: RFP-05/RFP-05M (for multiple probes), RFP-04 (for single dedicated probe).
Accessories:
Insulated Modem IM-01 (for RFP-05M).
Optical Digital Link Kit ODLK-01 (for RFP-05).
PC Link Kit PCLK-01 (for RFP-04).
Fiber Optic Link Kit FOLK-02 (for RFP-05M).
Fiber Optic Link Kit FOLK-01 (for RFP-05, RFP-04).
RF Transmitter Certification (Broadband)
Field strength measurements around power transmitters
Environment:
In the field.
Requirements:
Isotropic probes.
Portability.
Traceable Calibration (NIST, UK NPL).
Probes: PI-01LF (50 KHz-3 GHz), PI-01 (200 KHz-3 GHz), PI-01E (100 KHz-6 GHz),
PI-03 (3 MHz-18 GHz), PI-05 (1 MHz-40 GHz).
Meters: RFP-05/RFP-05M (for multiple probes), RFP-04 (for single dedicated probe).
Accessories:
GPS Receiver RPS-R (for RFP-05, RFP-05M).
Frequency Counter FC-01.
Insulated Modem IM-01 (for RFP-05M).
Optical Digital Link Kit ODLK-01 (for RFP-05).
PC Link Kit PCLK-01 (for RFP-04).
Portable Data Loggers DL-01, DL-02, DL-03 (for RFP-04).
RF Safety (except wearable personal safety)
Field monitoring for industrial environment safety compliance
Environment:
Industrial floor or labs.
Requirements:
Isotropic probes.
Traceable calibration (NIST, UK NPL).
Products:
Probes PI-01LF (50 KHz-3 GHz), PI-01 (200 KHz-3 GHz), PI-01E (100 KHz-6 GHz),
PI-03 (3 MHz-18 GHz), PI-05 (1 MHz-40 GHz), Magnetic field probe PI-H1 (500 KHz-50 MHz).
Meters: RFP-05/RFP-05M (for multiple probes), RFP-04 (for single dedicated probe).
Accessories:
Insulated Modem IM-01 (for RFP-05M).
Optical Digital Link Kit ODLK-01 (for RFP-05).
PC Link Kit PCLK-01 (for RFP-04).
Enviromental and RF “Smog” Monitoring
Monitoring of the environmental RF spectrum, selective or broadband
Environment:
In the field, industrial or living spaces, portable or permanently installed, networked.
Requirements:
Isotropic probes, isotropic antenna.
Traceable calibration (NIST, UK NPL).
Ability to operate while AC/DC powered and PC network connected.
Products:
Probes PI-01LF (50 KHz-3 GHz), PI-01 (200 KHz-3 GHz), PI-01E (100 KHz-6 GHz),
PI-03 (3 MHz-18 GHz), PI-05 (1 MHz-40 GHz), Magnetic field probe PI-H1 (500 KHz-50 MHz).
Meters: RFP-05/RFP-05M (for multiple probes), RFP-04 (for single dedicated probe).
Isotropic Antenna OFA-S/SE (30 MHz-3 GHz).
Selective Field Analyzer SFA-S/SE.
Accessories:
Insulated Modem IM-01 (for RFP-05M).
Optical Digital Link Kit ODLK-01 (for RFP-05).
PC Link Kit PCLK-01 (for RFP-04).
Portable Spectrum Analyzer (for OFA-S/SE).
Laptop PC (for SFA-S/SE), unless networked.
Order User Manuals or Other Documents
Smart Fieldmeter® and Smart Fieldmeter® Digital Probe Comparison:
Probes Chart 2014