Smart Fieldmeter® Digital RFP-05M

 

Smart Fieldmeter® Digital RFP05M

Electromagnetic field monitor having flexible and expandable architecture, state of the art design with convenience and simplicity for users on a budget.

SFD can be used for evaluation and measurements of EM fields for:

  • • Safety and regulatory assessment of AM/FM/TV and GSM cellular transmitters.
  • • Safety and Regulatory assessment of microwave ovens and RF heating equipment.
  • • Monitoring of the RF radiation from industrial, scientific and medical equipment.
  • • Monitoring of RF fields from GTEM cells and antennas for EMC testing of consumer, industrial, automotive and military products.
  • • Data logging of RF fields during Electrosmog testing and environmental monitoring in stand alone and remotely controlled testing sites.
  • • Personal RF field monitoring and protection.

Meter Power 2  Meter Logo 2 SFD_Large_Screen promo

Main Features

• Model RFP-05M is a development of the model RFP-05 and has two main advantages:

1. Compatibility with Insulated Modem (IM) accessory, allowing both fiber optic and USB RF isolated bidirectional control and battery charging without any additional wires coming out of the meter.

2.  Graphical display to plot the data real time.

  • Operates with and stores the data of multiple probes, both current and future models.
  • Large dynamic range with autoranging and auto-zero functions offers high accuracy and simple operation.
  • Advanced programmable data sampling with time and space averaging allows monitoring and recording of time variable signals.
  • Internal data logging with removable flash memory card offers programmable and practically unlimited data storage.
  • Serial bidirectional data port and IR remote control for PC data transfer and wireless instrument control.
  • Bright color OLED display with good visibility can be set to display only the information important to the user.
  • Portable lightweight design with detachable isotropic probe and two-cell AA primary or rechargeable battery offers flexibility and advantages in the field.

 

Smart Fieldmeter® Digital RFP-05M

• RFP-05M can operate with multiple probes, both current and future models.

  • Calibration factors for multiple probes are stored internally and can be updated from SD card by the user.

• Extremely large SFD dynamic range with auto-ranging function offers high accuracy and simple operation without any additional switching.

• Advanced programmable data sampling with time averaging and spatial averaging allows monitoring and recording of time variable signals to comply with various RF safety and regulatory standards.

Internal data logging with removable memory card provides programmable and practically unlimited data storage. No PC isneeded for data recording – log the data and read it later.

• Unique auto-zero function can be operated either automatically or manually even in the presence of the strongest RF fields, thus ensuring the high sensitivity and long term stability.

Serial bidirectional data port with IM Insulated Modem option can be used for PC bidirectional data transfer and instrument control.  Choose between RF isolated USB option (IM-USB) or USB and fiber optic accessory link (FOLK-02).

IR remote control allows SFD control and operation from a distance – no hands, no wires (Optional).

  • Sound alarm with variable threshold warns if the preset level is exceeded.

Portable lightweight design with detachable isotropic probe and standard battery (two AA primary or rechargeable cells) offers flexibility and advantages in the field.

• SFD can display the data both in field strength and power density units.

• Bright color OLED display can be set do display only the information important to the user. Maximized display mode ensures good visibility from a distance.

User friendly interface puts all frequently done functions at the upper screens making them easy to find and to use.

System Parameters of RFP-05M

RFP-05 PIC2        RFP-05 PIC1

Meter RFP-05M with probes (can support up to 4 probes at the same time):

  • Probe PI-01, Electric: 0.2 MHz – 3 GHz. 0.2 – 600 V/m.
  • Probe PI-01E, Electric: 0.1 MHz – 6 GHz. 0.3 – 600 V/m.
  • Probe PI-03, Electric: 3 MHz – 18 GHz. 0.8 – 800 V/m.
  • Probe PI-03P, Pulsed Electric: 100 MHz – 18 GHz. 70- 1400 V/m
  • Probe PI-01V, Electric: 800 -1900 MHz. 0.4 – 500 V/m.
  • Probe PI-H1, Magnetic: 0.5 MHz – 50 MHz. 0.05 – 20 A/m.
  • • Calibration Accuracy: +/-0.5 dB
  • • Linearity deviation: +/- 0.5 dB.
  • Unlimited onboard data storage on MMC compatible card.
  • • Battery life: 20-55 hours (Rechargeable).
  • • Warranty 1 year.

Meter Bottom

• US NIST (USA National Institute of Standards) / UK NPL (UK National Physical Laboratory) traceable certificate is supplied with every unit.

Purchasing the Smart Fieldmeter® Digital

You may find more information about our products to buy the Smart Fieldmeter® Digital  from our web site: www.emctd.comTo inquire about Smart Fieldmeter® Digital send us e-mail , or give us a call: 508-292-1833. We can arrange the demonstration of Smart Fieldmeter® Digital by our distributor in your country. Our mail address:

EMC Test Design, LLC® P.O. Box 600532, Newton, MA 02460, USA.

LOGO PIC1

Smart Fieldmeter® Digital RFP-05M 

 

Calibration Details: 

– Keep unit calibrated. We recommend calibration once a year in our UK NPL traceable EMC Test Lab.

All calibration tests are perormed in EMC Test Design, LLC test lab and are based on transferable field measuring probes and antennas traceable to United Kingdom National Physical Laboratory (UK NPL).

Probe PI-01/PI-01LF

1)  Meter/Probe Linearity 0.2-600 V/m @100 MHz/72.5 MHz,

2) Probe Frequency Correction Factors at 8-12 specified frequencies in the   frequency range 50 KHz-3 GHz.

3) Probe Rotational isotropicity at 100 MHz & 1900 MHz (@10 V/m).

Probe PI-01E

1)  Meter/Probe Linearity 0.2-600 V/m @100 MHz/72.5 MHz,

2) Probe Frequency Correction Factors at 12 specified frequencies in the   frequency range 100 KHz-6 GHz.

3) Probe Rotational isotropicity at 100 MHz & 1900 MHz (@10 V/m).

 

 Probe PI-03

1) Meter/Probe Linearity 0.5-800 V/m @100 MHz/72.5 MHz,

2) Probe Frequency Correction Factors at 24-30 specified frequencies in the frequency range 3 MHz-18 GHz.

3) Probe Rotational Isotropicity @ 100 and 1900 MHz (@10 V/m)..

Probe PI-03P

1) Meter/Probe Linearity 70-1400 V/m @942.5 MHz,

2) Probe Frequency Correction Factors at 25 specified frequencies in the frequency range 100 MHz-18 GHz.

3) Probe Rotational Isotropicity @ 100 and 1900 MHz (@100 V/m).

 

Probe PI-H1

1)  Meter/Probe Linearity 0.05-20 A/m @6.78 MHz,

2) Probe Frequency Responce at 17 specified frequencies in the frequency range 500 KHz-100 MHz.

3) Probe Rotational isotropicity at 6.78 MHz (@0.5 A/m).

 

– To convert the electric field strength E (V/m) into power density S (uW/cm2) use formula: S=E2/3.77. To calculate the value of the magnetic field H (far field region) use the relationship: E/H=377 Ohm. For convenience, the following table represents the conversion for working range of Smart Fieldmeter®:

Power density pic

.

RF Immunity Compliance/Precompliance

RF Immunity testing of electronic products to comply with consumer, military and industrial standards (CE Mark, MIL STD, RTCO, IEC, etc.)

 

Environment:

Typically – laboratory setting with or without a dedicated screen room.

Anechoic chamber in more advanced certified labs.

 

Requirements:

Isotropic probes.

Traceable calibration (NIST, UK NPL).

PC linked.

Fiber Optic Link Kit.

 

Products:

Probes PI-01LF (50 KHz-3 GHz), PI-01 (200 KHz-3 GHz), PI-01E (100 KHz-6 GHz),

PI-03 (3 MHz-18 GHz), Magnetic probe PI-H1 (500 KHz-50 MHz).

Meters: RFP-05/RFP-05M (for multiple probes), RFP-04 (for single dedicated probe).

 

Accessories:

Insulated Modem IM-01 (for RFP-05M).

Optical Digital Link Kit ODLK-01 (for RFP-05).

PC Link Kit PCLK-01 (for RFP-04).

Fiber Optic Link Kit FOLK-02 (for RFP-05M).

Fiber Optic Link Kit FOLK-01 (for RFP-05, RFP-04).

 

RF Transmitter Certification (Broadband)

Field strength measurements around power transmitters

 

Environment:

In the field.

 

Requirements:

Isotropic probes.

Portability.

Traceable Calibration (NIST, UK NPL).

 

Probes: PI-01LF (50 KHz-3 GHz), PI-01 (200 KHz-3 GHz), PI-01E (100 KHz-6 GHz),

PI-03 (3 MHz-18 GHz).

Meters: RFP-05/RFP-05M (for multiple probes), RFP-04 (for single dedicated probe).

 

Accessories:

GPS Receiver RPS-R (for RFP-05, RFP-05M).

Frequency Counter FC-01.

Insulated Modem IM-01 (for RFP-05M).

Optical Digital Link Kit ODLK-01 (for RFP-05).

PC Link Kit PCLK-01 (for RFP-04).

Portable Data Loggers DL-01, DL-02, DL-03 (for RFP-04).

 

RF Safety (except wearable personal safety)

Field monitoring for industrial environment safety compliance

 

Environment:

Industrial floor or labs.

 

Requirements:

Isotropic probes.

Traceable calibration (NIST, UK NPL).

 

Products:

Probes PI-01LF (50 KHz-3 GHz), PI-01 (200 KHz-3 GHz), PI-01E (100 KHz-6 GHz),

PI-03 (3 MHz-18 GHz), Magnetic field probe PI-H1 (500 KHz-50 MHz).

Meters: RFP-05/RFP-05M (for multiple probes), RFP-04 (for single dedicated probe).

 

Accessories:

Insulated Modem IM-01 (for RFP-05M).

Optical Digital Link Kit ODLK-01 (for RFP-05).

PC Link Kit PCLK-01 (for RFP-04).

 

Enviromental and RF “Smog” Monitoring

Monitoring of the environmental RF spectrum, selective or broadband

 

Environment:

In the field, industrial or living spaces, portable or permanently installed, networked.

 

Requirements:

Isotropic probes, isotropic antenna.

Traceable calibration (NIST, UK NPL).

Ability to operate while AC/DC powered and PC network connected.

 

Products:

Probes PI-01LF (50 KHz-3 GHz), PI-01 (200 KHz-3 GHz), PI-01E (100 KHz-6 GHz),

PI-03 (3 MHz-18 GHz), Magnetic field probe PI-H1 (500 KHz-50 MHz).

Meters: RFP-05/RFP-05M (for multiple probes), RFP-04 (for single dedicated probe).

Isotropic Antenna OFA-S/SE (30 MHz-3 GHz).

Selective Field Analyzer SFA-S/SE.

 

Accessories:

Insulated Modem IM-01 (for RFP-05M).

Optical Digital Link Kit ODLK-01 (for RFP-05).

PC Link Kit PCLK-01 (for RFP-04).

Portable Spectrum Analyzer (for OFA-S/SE).

Laptop PC (for SFA-S/SE), unless networked.

 

Pulsed RF Immunity in Automotive and Radar Applications

RF Field Strength Measurements of Fast Pulsed  (microseconds) Sources

 

Environment:

Typically – laboratory setting in screen room or anechoic chamber.

In field near pulsed RF sources.

 

Requirements:

Isotropic probes with fast (microseconds) response.

Traceable calibration (NIST, UK NPL).

 

Products:

Probe: PI-03P (100 MHz-18 GHz).

Meters: RFP-05/RFP-05M.

 

Accessories:

Insulated Modem IM-01 (for RFP-05M).

Optical Digital Link Kit ODLK-01 (for RFP-05).